E41-476 · Other Selection · Induction Heater Uneven Heating · ★★★
After heating a large bearing (outer diameter 600 mm) with an induction heater, the inner and outer rings differed by 30 ℃, and during installation the bearing jammed on the journal (outer ring not fully expanded).
When a standard induction heater (rated 15 kW) heats a large bearing, the alternating magnetic field induces eddy currents in the inner ring (which gets heated), while the outer ring heats by conduction. After 3 min the inner ring is 120 ℃ and the outer ring 90 ℃ (30 ℃ difference). Inner-ring expansion Δd_inner = α×d×ΔT = 12×10⁻⁶×400×120 = 0.576 mm; outer-ring expansion Δd_outer = α×D×ΔT = 12×10⁻⁶×600×90 = 0.648 mm. The expansion difference is small, but radial clearance changes during heating: inner-ring expansion reduces clearance (raceway radial dimension grows), outer-ring expansion increases it. Combined thermal expansion changes the C3-group clearance from 0.04 mm to about −0.02 mm (negative clearance), and the rollers are clamped during installation. After installation the bearing rotates stiffly and the raceway develops brinelling.
① Use a high-power induction heater for large bearings (≥30 kW, fast uniform heating).\n② Rotate the bearing during heating (heat inner and outer rings evenly, difference ≤10 ℃).\n③ Or use oil-bath heating (oil 100 ℃, heats the bearing as a whole, difference ≤5 ℃).\n④ Check bearing temperature after heating (infrared, confirm inner/outer ring difference ≤10 ℃).\n⑤ If jammed during installation, tap the inner-ring end face lightly with a copper bar and push in; if it cools, reheat with the heater before installing.
FT_Machine Design Handbook