Improper Handwheel Selection Causes Excessive Operating Torque (Valve Handwheel)

E41-755 · Other Selection Topics · Valve Handwheel Operating Torque · ★★★

Problem Symptom

The handwheel of a DN200 gate valve (Φ300mm) required the operator to use a force bar to open the valve (about 500N of effort against a standard of ≤360N).

Root Cause

With a handwheel diameter D=300mm the operating force is F=T/(D/2)=200/(0.15)=1333N (T = valve opening torque 200Nm), which is far above the standard ≤360N. Four times the standard effort, the operator had to use a force bar (1m long) to open it, but the force bar put an additional bending stress on the valve stem (the Φ30mm stem deflects in bending). The handwheel diameter should be designed for an operating force of ≤360N: D_min=2×T/F_max=2×200/360=1.11m, i.e. a 1.1m handwheel (a DN200 gate valve is normally fitted with a Φ500mm handwheel and still needs considerable effort). A valve with a worm gear reducer should be selected (a 4:1 reduction cutting the handwheel force to 333N).

Correct Solution

1) Re-check all the parameters against the correct selection specification;
2) Confirm that the duty load, environment and life all meet the design requirements;
3) Select a reliable brand and a suitable model;
4) Verify the installation and operating conditions;
5) Inspect and maintain the equipment at regular intervals after commissioning.

Checklist

References

FT_Mechanical Design Handbook

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL