E41-754 · Other Selection Topics · Manual Chain Hoist Overload · ★★★★★
When a manual chain hoist (rated 1t) lifted a 1.5t workpiece the chain broke suddenly and the workpiece fell, injuring a person.
The chain (grade 80, Φ8mm) has a breaking load of ≥32kN, and a 1.5t load corresponds to a tension of 14.7kN, giving a safety factor S=32/14.7=2.18, below the standard safety factor of 4. A 50% overload puts the chain stress at σ=14.7×10³/(2×π×0.004²)=146MPa (the minimum breaking stress of grade 80 chain is 800MPa), so σ=146MPa << 800MPa. The actual reason for the fracture is that the chain had never been lubricated (two years of use with no lubrication at all), so the wear between the link plates and the pins reduced the plate thickness from 4mm to 3mm (a 25% reduction in cross-section), while the plates also corroded (a damp storage environment), with 0.3mm deep rust pits → stress concentration factor Kt=3 → local stress σ_peak=146×3=438MPa. With the three factors of 50% overload, corrosion and wear, and the lifting impact (impact factor 1.3), σ_peak=438×1.3=569MPa, close to the fatigue limit of grade 80 chain (about 600MPa), and after about 3×10⁴ lifting cycles the link plate fractured in fatigue.
1) Re-check all the parameters against the correct selection specification;
2) Confirm that the duty load, environment and life all meet the design requirements;
3) Select a reliable brand and a suitable model;
4) Verify the installation and operating conditions;
5) Inspect and maintain the equipment at regular intervals after commissioning.