E41-753 · Other Selection Topics · High Temperature Coupling Elastomer · ★★★★
A coupling in a dryer drive (jaw type flexible coupling with a polyurethane elastomer) ran for one month at an ambient temperature of 80℃, after which the elastomer deformed and the coupling failed.
The polyurethane elastomer (hardness Shore A95) has an allowable working temperature of -20~80℃, so at an ambient temperature of 80℃ it is close to the limit. The coupling generates internal friction heat while transmitting torque (about 5℃ of self-heating), giving an actual temperature of 85℃. At 85℃ the compression set of the polyurethane rises from 20% to 60% (three times). Under sustained high temperature the elastomer is crushed (the thickness falls from 10mm to 7mm), the elasticity is lost → the cushioning capability falls → impacts occur when the torque is transmitted → the elastomer is destroyed faster → after about one month the elastomer cracks.
1) Re-check all the parameters against the correct selection specification;
2) Confirm that the duty load, environment and life all meet the design requirements;
3) Select a reliable brand and a suitable model;
4) Verify the installation and operating conditions;
5) Inspect and maintain the equipment at regular intervals after commissioning.
FT_Mechanical Design Handbook