E41-752 · Other Selection Topics · Manual Valve Internal Leakage · ★★★
A newly installed manual globe valve (DN50, PN16) still leaked after being closed, and the disc sealing face had a 0.2mm scratch.
The sealing face of the valve (304 stainless overlay weld, hardness HRC35) was only turned and not ground after machining, and the flatness of the sealing face was 0.05mm (requirement ≤0.02mm). When the disc meets the seat sealing ring the 0.05mm flatness error means the sealing face does not contact locally (a gap of about 0.03mm). At a water pressure of 1.0MPa a jet forms at the gap and erodes it, and the erosion width of about 0.1mm damages the sealing face and increases the leakage. At procurement the sealing face inspection report (flatness check plus dye penetrant testing) was not requested from the manufacturer, and no tightness test was carried out before installation.
1) Re-check all the parameters against the correct selection specification;
2) Confirm that the duty load, environment and life all meet the design requirements;
3) Select a reliable brand and a suitable model;
4) Verify the installation and operating conditions;
5) Inspect and maintain the equipment at regular intervals after commissioning.