Defective Sealing Face on a Purchased Manual Valve Causes Internal Leakage (Valve Quality Issue)

E41-752 · Other Selection Topics · Manual Valve Internal Leakage · ★★★

Problem Symptom

A newly installed manual globe valve (DN50, PN16) still leaked after being closed, and the disc sealing face had a 0.2mm scratch.

Root Cause

The sealing face of the valve (304 stainless overlay weld, hardness HRC35) was only turned and not ground after machining, and the flatness of the sealing face was 0.05mm (requirement ≤0.02mm). When the disc meets the seat sealing ring the 0.05mm flatness error means the sealing face does not contact locally (a gap of about 0.03mm). At a water pressure of 1.0MPa a jet forms at the gap and erodes it, and the erosion width of about 0.1mm damages the sealing face and increases the leakage. At procurement the sealing face inspection report (flatness check plus dye penetrant testing) was not requested from the manufacturer, and no tightness test was carried out before installation.

Correct Solution

1) Re-check all the parameters against the correct selection specification;
2) Confirm that the duty load, environment and life all meet the design requirements;
3) Select a reliable brand and a suitable model;
4) Verify the installation and operating conditions;
5) Inspect and maintain the equipment at regular intervals after commissioning.

Checklist

References

FT_Mechanical Design Handbook

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL