Blocked Silencer Causes Equipment Overheating (Silencer Blockage)

E41-762 · Other Selection Topics · Air Compressor Inlet Silencer Blockage · ★★★

Problem Symptom

After one year of use the discharge temperature of an air compressor with an inlet silencer rose from 85℃ to 105℃ and the inlet resistance increased.

Root Cause

The sound absorbing wool (glass fibre) of the silencer (micro-perforated plate with absorbing wool) broke away in the long-term inlet airflow and the fibre fragments blocked the micro-perforated plate (hole diameter Φ2mm), reducing the effective flow area from 100% to 60%. The inlet resistance of the compressor rose from 1kPa to 8kPa and the intake fell from 3.5m³/min to 3.0m³/min (a 14% reduction), so the compression ratio rose and the discharge temperature increased by 20℃. At the same time dust accumulated inside the silencer (about 0.5kg of dust per year), further increasing the resistance.

Correct Solution

1) Re-check all the parameters against the correct selection specification;
2) Confirm that the duty load, environment and life all meet the design requirements;
3) Select a reliable brand and a suitable model;
4) Verify the installation and operating conditions;
5) Inspect and maintain the equipment at regular intervals after commissioning.

Checklist

References

FT_Mechanical Design Handbook