Insufficient Grout Strength Under the Foundation Bolts Causes Loosening (Equipment Foundation)

E41-763 · Other Selection Topics · Equipment Foundation Bolts · ★★★★

Problem Symptom

After three months of running the foundation bolts (M36×1000mm) of a large fan foundation loosened and cracks appeared in the grout.

Root Cause

The grout under the foundation bolts (C40 non-shrink grout) reached a strength of 35MPa after seven days of curing (against an expected 40MPa), but the grout layer was 100mm thick (recommended ≤50mm). Thick grout shrinks by 0.05% during hardening (a 100mm thickness shrinks by 0.05mm), producing a micro-gap (about 0.02mm) at the interface between the bolt and the foundation. The vibration of the running fan (velocity 10mm/s) makes the bolt fret in the micro-gap and after about three months the bond between the grout and the bolt is destroyed (fretting wear 0.1mm deep), so the bolt loosens (the preload falls from 800kN to 300kN).

Correct Solution

1) Re-check all the parameters against the correct selection specification;
2) Confirm that the duty load, environment and life all meet the design requirements;
3) Select a reliable brand and a suitable model;
4) Verify the installation and operating conditions;
5) Inspect and maintain the equipment at regular intervals after commissioning.

Checklist

References

FT_Mechanical Design Handbook