E41-764 · Other Selection Topics · Lifting Lug Fracture · ★★★★★
During the lifting of a 5t machine, the welded lifting lug (Q235, plate 12mm thick, Φ40mm hole) fractured at the weld and the machine fell.
Lug capacity check: each of the two lugs carries 2.5t, so the tension is F=2500×9.8=24.5kN. The shear stress in the lug weld (fillet weld, leg height 8mm, weld length 100mm×2 sides=200mm) is τ=F/(0.7×h×L)=24500/(0.7×8×200)=21.9MPa. The allowable shear stress of Q235 is [τ]=100MPa, giving a safety factor S=100/21.9=4.6, which appears safe. However, the weld had defects: the actual leg height was only 5mm (against a design 8mm), so the effective weld area was reduced by 37.5% and τ_actual=24500/(0.7×5×200)=35MPa, S=100/35=2.86, still above 2. The reason for the fracture is that the sling was applied at only 30° to the horizontal (≥60° recommended), so the lug carried a vertical component of 24.5kN and a horizontal component of 42.4kN (F_h=F/tan30°=24.5/0.577=42.4kN). The horizontal component produced a bending stress in the lug plate σ_b=M/W=42.4×10³×0.02/(12×0.012²/6)=848/0.000288=2.94MPa, which is very small. But the horizontal force produces a large additional tensile stress at the weld root: τ_total=√(τ_v²+τ_h²)=√(35²+(42.4×10³/(0.7×5×200))²)=√(1225+36.7)=35.5MPa, S=100/35.5=2.82, still above 2. The actual cause of the fracture is that no bevel was prepared for welding (a 12mm plate should have a single V bevel), so the weld penetration was only 3mm (a fillet weld, not fully penetrated) and the effective leg was only 3mm → τ=24500/(0.7×3×200)=58.3MPa, and including the horizontal component τ=√(58.3²+(42.4×10³/(0.7×3×200))²)=√(3399+102)=59.2MPa, S=100/59.2=1.69. With the lifting impact factor of 1.3, S=1.3 no longer meets the requirement and the weld fractured.
1) Re-check all the parameters against the correct selection specification;
2) Confirm that the duty load, environment and life all meet the design requirements;
3) Select a reliable brand and a suitable model;
4) Verify the installation and operating conditions;
5) Inspect and maintain the equipment at regular intervals after commissioning.
FT_Mechanical Design Handbook