E41-768 · Other Selection · Bolt Preload Insufficient · ★★★
The newly installed air-compressor foundation bolts (M30×600 mm, grade 8.8) loosened after 1 week; preload dropped from 360 kN to 200 kN.
The foundation bolts were not tightened in steps (tightened to 600 Nm at once), so the contact surfaces were not fully seated (micro-asperities not completely crushed); under operating vibration the surfaces seated further, losing preload. The correct method is 3-stage tightening (50% → 75% → 100% torque), 30 min apart, so micro-asperities are fully crushed. Tightening straight to 600 Nm gives embedment loss about 50 μm; bolt elastic elongation ΔL = F×L/(E×A) = 360000×0.6/(206000×π×0.015²) = 216000/145.5 = 1484 μm (about 1.5 mm); the 50 μm embedment is 50/1484 = 3.4% of elastic elongation, losing preload 360000×3.4% = 12.2 kN. Actually after 1 week preload dropped to 200 kN (44% loss), meaning besides embedment loss there was also vibration relaxation (nut self-loosening).
① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning