E41-769 · Other Selection · Coupling Alignment Error · ★★★
After using a laser alignment instrument to align a motor–pump coupling, vibration increased within 1 month; measured radial misalignment was 0.08 mm.
The laser alignment instrument was operated without temperature compensation: motor (cold 25 ℃) and pump (cold 25 ℃) were aligned to radial deviation 0.02 mm. After operation the motor rose to 75 ℃ (50 ℃ rise) and the pump to 45 ℃ (20 ℃ rise). Motor center rise Δh_motor = α×ΔT×H = 12×10⁻⁶×50×315 (motor center height) = 0.189 mm. Pump center rise Δh_pump = 12×10⁻⁶×20×250 = 0.060 mm. Hot misalignment = 0.189 − 0.060 + 0.02 = 0.149 mm (no hot-expansion compensation reserved during cold alignment). The standard requires reserving the hot-expansion-difference compensation in the cold state (here the motor should be set 0.13 mm higher than the pump).
① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning
FT_Machine Design Handbook