E41-771 · Other Selection · Vibration Monitoring Error · ★★★
A vibration sensor (accelerometer) was mounted on the fan bearing housing, but the monitoring data stayed very small (0.5 mm/s) while the vibration felt by hand was large.
The vibration sensor (ICP accelerometer, sensitivity 100 mV/g) was magnetically mounted on the bearing-housing cover (cover wall 3 mm) instead of directly on the bearing-housing body (wall 20 mm). The cover has low local stiffness, so the sensor measured the cover local vibration (frequency > 1000 Hz) rather than the housing overall vibration (main energy at 50–500 Hz). The cover local vibration above 1000 Hz has very small amplitude (about 0.1 g), while the housing vibration acceleration at 100 Hz is about 2 g; the 2 g signal was attenuated 90% by the local resonance of the 3 mm thin plate. Also the magnetic mount had insufficient attraction (magnet diameter Φ8 mm, force 10 N), so under high-frequency vibration relative motion occurred between sensor and cover → distorted measurement.
① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning
FT_Machine Design Handbook