E41-772 · Other Selection · Guard Poor Ventilation · ★★★
The motor guard (stainless steel mesh) had insufficient ventilation area, and the motor operating temperature rose from normal 80 ℃ to 105 ℃.
The guard is a stainless steel woven mesh (wire diameter Φ1.5 mm, mesh 6×6 mm, ventilation area about 50%), installed 50 mm in front of the motor cooling-fan inlet. Cooling airflow Q = v×A×η = 3×π×0.2²×0.5 = 0.188 m³/s (v = 3 m/s, A = fan inlet area 0.1256 m², η = 0.5 ventilation efficiency). The guard reduced ventilation efficiency from 0.8 to 0.5, cutting airflow 37.5%. With insufficient airflow motor cooling efficiency dropped, temperature rise increasing from 55 K to 80 K (ambient 25 ℃ → 80 ℃ → 105 ℃); winding temperature reached 105 ℃. Although class F insulation (allowable 155 ℃) was not exceeded, life is reduced by high temperature (halved per 10 ℃ rise).
① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning
FT_Machine Design Handbook