E41-776 · Other Selection · Service Platform Load Capacity · ★★★★
The equipment service platform (steel grating + channel-steel support) deformed when three maintenance workers stood on it together; the grating sank 50 mm.
The service platform was designed for 2 kN/m² (1 person/m²), but actually three people stood together in about 1 m² (concentrated load about 3×80 kg = 2.4 kN) plus about 50 kg tools, total 2.9 kN. 2.9 kN > 2 kN/m², 45% overload. The steel grating (G255/30/100, flat bar 25×5 mm, pitch 30 mm) has span L = 1.2 m and allowable uniform load 4 kN/m² (manufacturer data). 4 > 2.9, theoretically safe. But the channel-steel support ([10 channel, span 2 m) deflection δ = 5×q×L⁴/(384×E×I) = 5×0.0029×10⁶×2⁴/(384×206000×198×10⁴) = 232000/(1.56×10¹²) = 0.00015 m = 0.15 mm, very small. The actual 50 mm sink came from the grating-to-support connection (weld points fallen off) plus the grating own plastic deformation. The grating was welded to the channel at only 3 spots (1 per side, leg length 30 mm), far fewer than the recommended 5 per side. Under the 2.9 kN concentrated load the welds failed one by one → the grating separated from the support → sank.
① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning
FT_Machine Design Handbook