E41-789 · Other Selection · Tube Fitting Leak · ★★★
The hydraulic oil-line fitting (M22×1.5 metric thread) and the valve-block port (G1/2 imperial pipe thread) could not seal after screwing together, leaking continuously.
The metric thread M22×1.5 (thread angle 60°, pitch 1.5 mm) and the imperial pipe thread G1/2 (thread angle 55°, pitch 1.814 mm) cannot match. G1/2 major diameter about 20.96 mm, M22 major 22 mm (1 mm difference), pitch difference 0.314 mm; after tightening they only partially engage (thread interference). The joint seal failed after screwing in (O-ring sealing face not seated). Wrong reason: the maintenance worker assumed M22 and G1/2 are close enough to be interchangeable and did not check the thread specification.
① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning
FT_Machine Design Handbook