Knowledge Base › Selection Error Cases › Wrong pressure-gauge range selection for leak test (gauge selection)

Wrong pressure-gauge range selection for leak test (gauge selection)

E41-788 · Other Selection · Pressure Gauge Range · ★★★

Problem Description

The hydrostatic-test pressure gauge (range 0–40 MPa, grade 1.6) barely moved its pointer at the 1.5 MPa test pressure.

Root Cause

Gauge range 40 MPa, measured pressure 1.5 MPa, pointer deflection angle = 1.5/40×270° ≈ 10°, reading accuracy extremely low (grade 1.6 means max error ±0.64 MPa = ±64% of reading!). Correct choice: the measured value should be within 1/3–2/3 of the range, i.e., the gauge range should be between 1.5×3 = 4.5 MPa and 1.5×1.5 = 2.25 MPa; select a 0–4 MPa gauge (1.5 MPa gives 101° deflection, error ±0.064 MPa = ±4.3% of reading).

Corrective Solution

① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning