Knowledge Base › Selection Error Cases › Cooling failure caused by a reversed cooling fan (fan rotation direction)

Cooling failure caused by a reversed cooling fan (fan rotation direction)

E41-807 · Other Selection · Fan Reversal · ★★★

Problem Description

After installing the motor's independent cooling fan, the motor temperature rose from a normal 75 °C to 105 °C; inspection found the fan was running in reverse.

Root Cause

The independent cooling fan's three-phase power wiring had the wrong phase sequence (two phases swapped), so the fan rotated opposite to the design direction. When an axial fan runs in reverse, its airflow is only 30–40% of forward rotation (the blade mounting angle is designed for forward blowing; in reverse the blades have negative angle of attack → stall → airflow drops sharply). The motor cooling airflow dropped from 1.5 m³/s to 0.5 m³/s, cooling efficiency fell by 67%, and the motor temperature rise went from 50 K to 80 K.

Corrective Solution

① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning

Checklist

Reference

FT_Machine Design Handbook

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »