Knowledge Base › Selection Error Cases › Oil mist overflow caused by excessive oil supply in the oil mist lubrication system (oil mist lubrication)

Oil mist overflow caused by excessive oil supply in the oil mist lubrication system (oil mist lubrication)

E41-806 · Other Selection · Oil Mist Overflow · ★★★

Problem Description

In the oil mist lubrication system (lubricating bearings), large amounts of oil mist escaped from the bearing housing seals, forming an oil film on the workshop floor.

Root Cause

The oil mist lubrication supply was set at 0.5 L/day (per bearing), but the bearing actually needs only 0.1 L/day. The excess oil mist condensed into oil droplets inside the bearing cavity (oil mist concentration too high, mist condensing on the cavity wall) and could not be expelled with the compressed air. The accumulated oil droplets overflowed through the bearing housing seal gaps. The oil mist generator's (vortex type) supply regulating valve had an inaccurate scale (showed 0.5 L/day but actually delivered 1.2 L/day) and had not been calibrated with a flowmeter.

Corrective Solution

① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning

Checklist

Reference

FT_Machine Design Handbook