Knowledge Base › Selection Error Cases › Excessive oil mist emission caused by improper oil mist separator filter selection (oil mist separ

Excessive oil mist emission caused by improper oil mist separator filter selection (oil mist separation)

E41-815 · Other Selection · Oil Mist Separation Failure · ★★★

Problem Description

The oil mist separator (treatment airflow 2000 m³/h, required filtration efficiency ≥ 99%) discharged oil mist at 30 mg/m³ (standard ≤ 10 mg/m³).

Root Cause

The oil mist separator used a glass-fiber filter (filtration rating 5 μm); its capture efficiency for oil mist particles below 5 μm (main particle diameter 0.5–3 μm, 80% of total) was only 85%. Overall filtration efficiency = 80%×85% + 20%×99% = 68% + 19.8% = 87.8% < 99%. Discharge concentration 30×87.8% = 26.3 mg/m³, close to 30 mg/m³ (plus regeneration emissions, etc.). A high-efficiency HEPA filter (H13 grade, rating 0.3 μm, efficiency ≥ 99.97%) should be used, or an electrostatic oil mist purifier (efficiency ≥ 95%).

Corrective Solution

① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning

Checklist

Reference

FT_Machine Design Handbook

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »