E41-815 · Other Selection · Oil Mist Separation Failure · ★★★
The oil mist separator (treatment airflow 2000 m³/h, required filtration efficiency ≥ 99%) discharged oil mist at 30 mg/m³ (standard ≤ 10 mg/m³).
The oil mist separator used a glass-fiber filter (filtration rating 5 μm); its capture efficiency for oil mist particles below 5 μm (main particle diameter 0.5–3 μm, 80% of total) was only 85%. Overall filtration efficiency = 80%×85% + 20%×99% = 68% + 19.8% = 87.8% < 99%. Discharge concentration 30×87.8% = 26.3 mg/m³, close to 30 mg/m³ (plus regeneration emissions, etc.). A high-efficiency HEPA filter (H13 grade, rating 0.3 μm, efficiency ≥ 99.97%) should be used, or an electrostatic oil mist purifier (efficiency ≥ 95%).
① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning
FT_Machine Design Handbook