E41-816 · Other Selection · Magnetic Switch Signal Loss · ★★★

Problem Description

The cylinder magnetic switch (reed switch with contacts, sensing distance 5 mm) frequently lost signal when the piston moved at high speed (1 m/s).

Root Cause

The 5 mm sensing distance of the magnetic switch is based on static magnetic-field testing. At high piston speed (1 m/s), the time for the magnetic ring to pass the switch is t = sensing-zone length / speed = 5 mm / (1 m/s) = 5 ms. The reed switch response time (pull-in + release) is about 10 ms; since 5 ms < 10 ms, the switch cannot fully pull in and release while the ring passes, so it cannot output a valid switching signal. A contactless solid-state switch (Hall-effect or GMR, response time < 0.1 ms) should be selected, or the cylinder speed should be reduced below 0.5 m/s.

Corrective Solution

① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning

Checklist