The VFD-driven motor (45 kW) produced a harsh high-frequency noise (about 8 kHz) during operation, and operators complained.
The VFD carrier frequency was set to 4 kHz (factory default); the motor windings produced electromagnetic noise (harmonic components at 4 kHz and 8 kHz) under the 4 kHz PWM excitation. The human ear is most sensitive to 4–8 kHz noise (peak of the hearing curve). Raising the carrier frequency to 12 kHz shifted the electromagnetic noise to 12 kHz and 24 kHz (above the ear's sensitive range of 20 kHz), reducing noise from 82 dB(A) to 68 dB(A). But raising the carrier frequency increased VFD losses (IGBT switching loss from 400 W to 800 W), so the VFD had to be derated by 5%.
① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning