E41-824 · Other Selection · Undersized Gasket Inner Diameter · ★★★
The pipe flange (DN100, PN16) used a spiral-wound gasket (inner diameter Φ108 mm); the pipe medium (water) flow dropped from the design 20 m³/h to 18 m³/h.
The actual inner diameter of a DN100 pipe is about Φ102 mm, and the gasket inner diameter Φ108 mm > Φ102 mm, so in theory it would not obstruct flow. But because the gasket was installed eccentrically (offset from pipe center by about 5 mm), the actual effective flow area of the gasket bore (the overlap region between gasket bore and pipe wall) was reduced by about 50%. The eccentricity caused one side of the gasket's winding band to protrude into the pipe bore (a Φ108 mm gasket, after 5 mm eccentricity, protrudes about 5 mm on one side), reducing the effective flow area from π×0.051² = 0.00817 m² to about 0.0055 m² (a 33% reduction), increasing the resistance coefficient → flow dropped from 20 m³/h to 18 m³/h.
① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning
FT_Machine Design Handbook