E41-825 · Other Selection · Misaligned Pulley Faces · ★★★
In the fan belt drive, the belt drifted toward the motor side (offset 3 mm), and the motor-side pulley face wore severely (2 mm more than the fan side).
The pulley face misalignment between motor and fan was 3 mm (motor pulley 3 mm forward). In the drive the belt slid from the fan pulley toward the motor pulley (the belt has a self-centering tendency → drifting toward the larger-diameter side) and rubbed on the motor pulley face. The friction generated heat (about 50 °C rise), accelerating belt aging (rubber hardening). Meanwhile the belt's diagonal travel produced a side force (about 50 N), imposing an additional bending moment on the motor shaft and accelerating bearing wear.
① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning
FT_Machine Design Handbook