E41-826 · Other Selection · Incorrect Bleed Valve Location · ★★★
The hydraulic line had no bleed valve at its high point; during operation gas accumulated at the line's highest point, producing a 5% air entrainment rate → cylinder stick-slip (crawling).
The highest point of the hydraulic line (1.5 m above the pump outlet) had no automatic bleed valve; bubbles (from new oil plus air carried by the return line) floated up and accumulated there. After accumulation, a gas cavity formed (volume about 0.5 L); when system pressure rose, the cavity compressed (Boyle's law P₁V₁ = P₂V₂, V₂ = 0.5×0.1/16 = 0.0031 L), shrinking and not affecting operation. But after shutdown the pressure dropped to 0 and the cavity expanded back to 0.5 L → oil was pushed out → the system drew in air on next start-up → 5% air content.
① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning
FT_Hydraulic & Pneumatic Design