E41-827 · Other Selection · Weld Lack of Penetration · ★★★★
An X-ray inspection of the thick-plate (20 mm) butt weld found a lack-of-penetration defect (unfused at the weld root, depth about 5 mm).
A 20 mm thick plate was prepared with a single-V groove (groove angle 30°, root face 2 mm) for manual arc welding. The 30° groove angle was too small (recommended 45–60°); the electrode (Φ3.2 mm) could hardly reach the groove root, and the arc could not melt the base metal on both sides of the groove root. The 2 mm root face was not fully melted during the root pass, leaving about 1.5 mm of lack of fusion. The weld's effective load-bearing section dropped from 20 mm to 15 mm (a 25% loss), and under load stress cracking may initiate from the defect.
① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning
FT_Machine Design Handbook