E41-618 · Gear Transmission Selection · Overhung Gear Drive · ★★★★
After 3 months of operation, a cantilever-mounted gear (m=6 mm, Z=35) suffered a wedge-shaped tooth fracture running from one end to the other (tooth breakage from offset loading, with the fracture depth decreasing from one end of the tooth width to the other).
The gear is mounted overhung on the shaft end, with an overhang length L=150 mm and a shaft diameter of Φ50 mm. The gear width b=80 mm and the meshing force F_n=15000 N. The deflection at the overhung end δ=F_n×L³/(3×E×I)=15000×0.15³/(3×206×10⁹×π×0.025⁴/64)=15000×0.003375/(3×206×10⁹×1.92×10⁻⁸)=50.625/11865.6=0.00427 m=4.27 mm. The angular deflection of the shaft at the gear position is θ=δ/L=4.27/150=0.0285 rad≈1.63°. With the gear meshing at a 1.63° deflection, the load distribution across the gear width is extremely uneven (contact at one end, separation at the other), and the actual load-bearing tooth width is only about 20 mm (of the total 80 mm). With an equivalent tooth width b_eff=20 mm, the actual root stress σ_F=σ_F design×(b/b_eff)=design stress×4 times. Running at 4 times the stress, the gear failed by fatigue fracture after about 3 months (about 1.3 million cycles).
① The shaft-end deflection of an overhung gear should be ≤0.01 mm (precision drive) or ≤0.05 mm (general drive)\n② In this case the deflection of 4.27 mm >>0.05 mm, so the design must be improved\n③ Improvement plan: change to double support (bearings on both sides of the gear), reducing the overhang length from 150 mm to 0\n④ If overhung mounting is unavoidable: increase the shaft diameter (Φ50 → Φ80 mm, reducing the deflection to 1.0 mm)\n⑤ Use a crowned tooth (lead modification to compensate the offset load, with a modification amount of 0.02~0.05 mm)
FT_Gear Transmission Design