E41-635 · Gear Drive Selection · Large Gear Shrink Fit · ★★★★
When a large gear (m = 20 mm, outer diameter Φ2000 mm) was shrink-fitted onto its shaft, an axial crack about 150 mm long appeared in the gear bore, penetrating through the width of the gear rim.
The gear was heated to 250 °C (2 h on an electric heating plate), expanding its bore from Φ300 mm to Φ300.9 mm (linear expansion 12×10⁻⁶×250×300 = 0.9 mm). The shaft outer diameter was Φ305 mm (fit H7/s6, interference 0.04–0.08 mm). After heating, the gear bore Φ300.9 mm < the Φ305 mm shaft diameter, so it was still an interference fit (about 4.1 mm negative clearance). The operator misjudged the temperature; the actual heating temperature was insufficient (only 150 °C), so the bore expanded by only 0.54 mm (300.54 mm), a difference from the shaft diameter of −0.46 mm. During forced assembly, the gear bore developed a huge hoop tensile stress under the interference force, σ_t = δ×E/d = 0.46×206000/300 ≈ 316 MPa (δ = shaft diameter − bore diameter after expansion = 305 − 300.54 = 4.46 mm; no — actual interference = 305 − 300.54 = 4.46 mm/300 = 0.0149, σ_t = 0.0149×206000 ≈ 3069 MPa?? No. The interference (diameter difference) is 4.46 mm, but the relative interference on the 300 mm diameter is δ/d = 4.46/300 = 0.0149, so the hoop tensile stress σ_t = E×δ/d = 206000×0.0149 ≈ 3069 MPa, far exceeding the fracture strength of QT600-3 (600 MPa); once the stress exceeds the material strength, it cracks directly. This is why an axial through-crack occurred in the gear bore. The correct interference should be 0.04–0.08 mm (in the diametral direction), not 4.46 mm.
① For shrink fitting a large gear, the heating temperature must be calculated precisely: T = (δ+Δ)/α/d+20 °C (δ is the interference, Δ is the assembly clearance, taken as 0.1–0.2 mm)\n② For this case: heating temperature T = (0.06+0.15)/(12×10⁻⁶×300)+20 = 0.21/0.0036+20 ≈ 78 °C\n③ For the heating method, prefer an oil bath (good temperature uniformity) or induction heating (fast)\n④ The heating temperature must not exceed the gear tempering temperature (≤ 180 °C for carburized gears)\n⑤ During shrink fitting, measure the bore size with an inside micrometer and insert quickly once the expansion is confirmed sufficient
FT_Gear Transmission Design