Improper shrink fitting of a gear shaft causing bore cracking (large gear shrink fit)

E41-635 · Gear Drive Selection · Large Gear Shrink Fit · ★★★★

Problem Description

When a large gear (m = 20 mm, outer diameter Φ2000 mm) was shrink-fitted onto its shaft, an axial crack about 150 mm long appeared in the gear bore, penetrating through the width of the gear rim.

Root Cause

The gear was heated to 250 °C (2 h on an electric heating plate), expanding its bore from Φ300 mm to Φ300.9 mm (linear expansion 12×10⁻⁶×250×300 = 0.9 mm). The shaft outer diameter was Φ305 mm (fit H7/s6, interference 0.04–0.08 mm). After heating, the gear bore Φ300.9 mm < the Φ305 mm shaft diameter, so it was still an interference fit (about 4.1 mm negative clearance). The operator misjudged the temperature; the actual heating temperature was insufficient (only 150 °C), so the bore expanded by only 0.54 mm (300.54 mm), a difference from the shaft diameter of −0.46 mm. During forced assembly, the gear bore developed a huge hoop tensile stress under the interference force, σ_t = δ×E/d = 0.46×206000/300 ≈ 316 MPa (δ = shaft diameter − bore diameter after expansion = 305 − 300.54 = 4.46 mm; no — actual interference = 305 − 300.54 = 4.46 mm/300 = 0.0149, σ_t = 0.0149×206000 ≈ 3069 MPa?? No. The interference (diameter difference) is 4.46 mm, but the relative interference on the 300 mm diameter is δ/d = 4.46/300 = 0.0149, so the hoop tensile stress σ_t = E×δ/d = 206000×0.0149 ≈ 3069 MPa, far exceeding the fracture strength of QT600-3 (600 MPa); once the stress exceeds the material strength, it cracks directly. This is why an axial through-crack occurred in the gear bore. The correct interference should be 0.04–0.08 mm (in the diametral direction), not 4.46 mm.

Corrective Solution

① For shrink fitting a large gear, the heating temperature must be calculated precisely: T = (δ+Δ)/α/d+20 °C (δ is the interference, Δ is the assembly clearance, taken as 0.1–0.2 mm)\n② For this case: heating temperature T = (0.06+0.15)/(12×10⁻⁶×300)+20 = 0.21/0.0036+20 ≈ 78 °C\n③ For the heating method, prefer an oil bath (good temperature uniformity) or induction heating (fast)\n④ The heating temperature must not exceed the gear tempering temperature (≤ 180 °C for carburized gears)\n⑤ During shrink fitting, measure the bore size with an inside micrometer and insert quickly once the expansion is confirmed sufficient

Checklist

Reference

FT_Gear Transmission Design

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »