Knowledge Base › Selection Error Cases › Improper gear oil pump selection causing insufficient lubrication (gearbox oil supply system)

Improper gear oil pump selection causing insufficient lubrication (gearbox oil supply system)

E41-636 · Gear Drive Selection · Gearbox Lubrication Oil Supply · ★★★★

Problem Description

After half a year of operation, the gearbox lubrication pump (CB-B type gear pump) dropped in supply pressure from 0.4 MPa to 0.15 MPa, and the gearbox bearings burned out due to insufficient lubrication.

Root Cause

In long-term operation of the gear oil pump (CB-B16, rated flow 16 L/min @ 1450 rpm), the clearance between the pump gear end face and the pump cover increased from 0.03 mm to 0.12 mm due to wear. The increased clearance reduced the pump volumetric efficiency from 90% to 60%, so the actual oil supply dropped from 16×0.9 = 14.4 L/min to 16×0.6 = 9.6 L/min. The total oil demand at the gearbox lubrication points was about 12 L/min (bearing spray 6 L/min + gear spray 6 L/min), which the actual 9.6 L/min could not satisfy. Bearing oil supply was insufficient (actual only 4 L/min vs. the required 6 L/min), so the bearings ran starved, and the temperature rise went from 45 °C to 80 °C. At high temperature the oil viscosity dropped from VG320@40 °C to VG320@80 °C ≈ 55 cSt (a viscosity drop of about 80%), and the oil film thickness fell from 2 μm to 0.3 μm (less than twice the bearing roughness Ra0.4 μm), causing direct metal-to-metal contact → bearing burnout.

Corrective Solution

① The gear oil pump supply flow should be ≥ 1.5× the lubrication demand (safety factor)\n② In this case the oil demand is 12 L/min, so a pump with a rated flow ≥ 18 L/min should be selected (e.g. CB-B20)\n③ Inspect the oil pump periodically (check supply pressure and flow every 2000 h)\n④ A pressure drop from 0.4 MPa to 0.15 MPa signals reduced volumetric efficiency; replace the oil pump immediately\n⑤ Add a low-oil-pressure alarm switch (alarm or shutdown when pressure < 0.2 MPa)

Checklist

Reference

FT_Gear Transmission Design

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »