Knowledge Base › Selection Error Cases › Seizure caused by rising center distance from thermal deformation (high-temperature gear)

Seizure caused by rising center distance from thermal deformation (high-temperature gear)

E41-983 · Gear Drive Selection · High-Temperature Gearbox · ★★★★

Problem Description

A high-temperature gearbox heated up during operation; the center distance grew by Δa = 0.05 mm, consuming all the backlash, and the unit seized.

Root Cause

First, the center-distance thermal expansion Δa = α·a·ΔT = 11.5e-6×80×50 = 0.046 mm consumed the design backlash jn of 0.08 until it became negative. Second, the negative backlash caused dry rubbing, scuffing, and seizure. Third, seizure. [Root cause] No allowance was made for thermal expansion.

Corrective Solution

① The backlash of a high-temperature gear must deduct the thermal expansion Δa = α·a·ΔT
② Choose a larger backlash or a compensating structure
③ Insulate the housing to reduce the temperature
④ Match the material α
⑤ Do not omit a thermal-expansion allowance
⑥ Add temperature monitoring
⑦ If it jams, check thermal expansion