Knowledge Base › Selection Error Cases › Tooth fracture from overload (impact load)

Tooth fracture from overload (impact load)

E41-984 · Gear Drive Selection · Impact Gear · ★★★★

Problem Description

On an impact machine, a gear fractured at 3× the peak load, forcing a shutdown.

Root Cause

First, the impact peak exceeded the bending-fatigue limit σ_F, so the tooth fractured. Second, it broke. Root cause: the peak load was not checked.

Corrective Solution

① Check σ_F against the peak torque and keep a margin
② Soft start / flywheel to clip the peak
③ Carburize and quench to raise [σ_F]
④ Multiply by KA
⑤ Forbid sizing by steady load
⑥ Limit torque
⑦ If it breaks, check the peak load

Checklist