E41-985 · Gear Drive Selection · Enclosed Gear · ★★★
An enclosed gear pitted during service; noise rose, efficiency dropped, and it had to be replaced.
First, the contact stress σ_H=Z_E·Z_H·√(F_t/(b·d1)·(u+1)/u) exceeded the fatigue limit, so the surface spalled and pitted. Second, the pitting spread and noise increased. Root cause: σ_H too high.
① Verify σ_H=Z_E·Z_H·√(F_t(b·d1)(u+1)/u) ≤ [σ_H]
② Increase hardness / improve finish to reduce σ_H
③ Choose a larger d1/b to lower σ_H
④ Provide a high-quality oil film
⑤ Do not exceed the fatigue limit
⑥ Periodically inspect for pitting
⑦ If pitting appears, check σ_H
FT_Gear Transmission Design