Problem Description

A coupling had 0.3 mm misalignment; the resulting additional bending moment broke the teeth, causing a shutdown.

Root Cause

First, poor alignment imposed an additional bending moment M=F·e on the shaft and an extra load on the teeth, causing fracture. Second, it broke. Root cause: misalignment.

Corrective Solution

① Coupling alignment ≤ 0.05 mm
② Use laser alignment during installation
③ Use a flexible coupling to compensate for offset
④ Do not install with large misalignment
⑤ Check alignment
⑥ Ensure sufficient shaft stiffness
⑦ If it breaks, check alignment

Checklist

Reference