E41-644 · Belt Drive Selection · Fan Belt Tension · ★★★
The fan motor bearing (6310ZZ) failed every 3 months (design life 50000 h); inspection found the belt tension was excessive (design 500 N, measured 1200 N).
To eliminate belt slip, the installer increased the tension from the recommended 500 N to 1200 N (judging by feel that tighter was safer). The excessive tension imposed an extra radial force on the motor bearing of F_r_extra≈(1200-500)×2=1400 N (the tension difference across the two belt sides × 2). The bearing was originally designed for a radial force F_r0=800 N (rotor weight + the vector sum of one belt's tension); after the increase, F_r=800+1400=2200 N. The 6310ZZ has a basic dynamic load rating C=61.8 kN and a load ratio P/C=2200/61800=0.0356, giving a life L10=(C/P)³=(1/0.0356)³≈22175 (million revolutions), which at 1450 rpm gives L10h=22175×10⁶/(60×1450)≈2.55×10⁵ h—apparently still very long. In reality, however, the bearing also carries the additional bending moment from the belt drive (the pulley is overhung) and the bending stress at the shaft end, and the inner ring on the Φ55 mm shaft deflects under the excessive radial force so that the internal load distribution becomes uneven; the actual life drops to about 2000 h (3 months), matching the observed behavior.
① Belt tension must be measured with a tension gauge (never by feel)\n② Check the manufacturer's catalog for the recommended tension (500~600 N is normal for a B-type belt)\n③ Excessive tension eliminates slip but markedly shortens bearing and shaft life\n④ Belt drives should run slightly loose (2~3% slip is permissible; never operate with no slip at all)\n⑤ Check the tension once a week (belts stretch during initial service and need adjustment)
FT_Belt & Chain Drive Design