Knowledge Base › Selection Error Cases › V-belt bending-fatigue breakage caused by too small a small pulley (cooling-tower fan)

V-belt bending-fatigue breakage caused by too small a small pulley (cooling-tower fan)

E41-832 · Belt Drive Selection · Cooling-Tower Axial Fan · ★★★

Problem Description

A cooling-tower fan (motor 75 kW, 1480 rpm) used an A-profile V-belt with a small pulley d1 = 75 mm (exactly the allowable lower limit for an A-belt). After about three months the belt cracked longitudinally and broke, far short of its 1-year design life; the fracture lay at the bottom of the tensile layer and showed bending-fatigue characteristics. The shutdown disabled the cooling system and interrupted production cooling for half a day.

Root Cause

First, the V-belt bending stress σ_b = E_b·t/d1 is inversely proportional to d1: at d1 = 75 mm, σ_b is about 125/75 = 1.67× that at d1 = 125 mm, already approaching the fatigue limit of an A-belt. Second, the small-pulley bend frequency f_b = z·v/(π·d1); at a belt speed v = π·d1·n1/60000 = π·75·1480/60000 = 5.8 m/s, f_b = 1·5.8/(π·0.075) = 24.6 Hz — high-frequency bending. Third, although the centrifugal stress σ_c = ρ·v² = 1.1e-3·5.8² ≈ 0.037 MPa is negligible, the combined bending and centrifugal stress makes the bottom tensile layer's σ_total exceed the fatigue limit, so after about 3×10⁶ bending cycles (three months) a crack initiates, propagates, and the belt breaks. Root cause: d1 was taken at the allowable lower limit with no safety margin.

Corrective Solution

① The small-pulley diameter must be ≥ the belt type's allowable minimum with a margin (A-profile lower limit 75 mm, recommended ≥ 100 mm; for SPZ narrow V-belts the lower limit is 63 mm, recommended ≥ 90 mm)
② For the same power, prefer narrow V-belts (SPZ/SPB): higher per-belt capacity, fewer belts, lower bending stress
③ Check the bending stress σ_b = E_b·t/d1 ≤ the allowable value, and keep the bend frequency f_b = z·v/(π·d1) from rising too high
④ Belt speed v should be 5–25 m/s; if too low it amplifies the bend frequency, so increase d1 or adjust the motor speed
⑤ Use quenched-and-tempered steel for the small pulley, with groove-surface roughness Ra ≤ 1.6, to reduce local stress concentration
⑥ After 50 h of run-in, retighten the new belt to the design tension to take up the initial elongation
⑦ Every 2000 h, shut down and visually inspect the belt sides for cracks; replace once a crack reaches the cord layer; reducing the load temporarily is only a stopgap