E41-833 · Belt Drive Selection · Boiler Feedwater Pump · ★★★★

Problem Description

A boiler feedwater pump (motor 90 kW, large load fluctuation) originally had six B-profile V-belts; at full load the belts slipped and smoked, and their working faces became glazed and gummy. They had to be replaced about every two months, and pump stoppages reduced boiler pressure, risking a boiler trip.

Root Cause

First, a single B-profile belt at d1 = 160 mm and v = 15 m/s has a rated power P1 ≈ 6.8 kW; with a service factor KA = 1.4 (severe vibration) the allowable power is P = P1/KAd·Kα ≈ 6.8/1.4·0.95 ≈ 4.6 kW, so six belts give only 27.6 kW < the actual shaft power of 90 kW. Second, the slip ratio ε rises above 3% with load, and the effective pull F_e = 1000·P/v = 1000·90/15 = 6000 N far exceeds the total F_e_max of the six belts = 6·z·A·E·ε ≈ 6·147·200·0.03 ≈ 5300 N. Third, the slip power P_slip = T·Δω ≈ 90 × 0.03 × 157 = 424 W turns into heat, raising the belt temperature above 150 ℃, accelerating aging so that it gums up in two months. Root cause: the number of belts was selected from the rated power instead of using the service factor.

Corrective Solution

① Belt count z ≥ P/(P1·Kα·KL/KAd); in this case z ≥ 90/(4.6) ≈ 20 belts (not recommended), so narrow V-belts should be adopted instead
② Switch to SPB narrow V-belts: single-belt P1 ≈ 11 kW, so z ≈ 90/(11/1.4·0.95) ≈ 12 belts suffice
③ The service factor KA must be applied (use 1.3–1.5 for shock and vibration); never size directly from the nameplate power
④ Check the effective pull F_e = 1000P/v ≤ z·F_e_max, with a 20% margin
⑤ For high power and many belts, switch to a direct coupling or a timing belt to reduce the belt count
⑥ Add a tensioner for automatic constant tension to compensate for belt elongation
⑦ Install shaft-power/current monitoring to give a slip warning once it exceeds 80% of rated