E41-834 · Belt Drive Selection · Screw Air Compressor · ★★★
A screw air compressor (37 kW) mistakenly used A-profile V-belts instead of the designed SPA narrow V-belts; within one week of operation several belts came out of their grooves and were thrown off. The main unit lost pressure, the production line lost air, and emergency repairs took 8 hours.
First, the machine's design transmitted torque is T = 9550·37/2930 = 120.6 N·m; a single A-profile belt allows T_A ≈ 30 N·m (at d1 = 90 mm), so four belts are needed; but the A-belt's 34° wedge angle does not match the pulley grooves (originally designed with SPA's 13° wedge angle). Second, the SPA grooves have a small groove angle and deep wedging, so an A-belt placed in them makes poor flank contact, with an effective friction force of only 60% of design: actual F_f_max = 0.6·z·F0·μ·e^(μθ) = 0.6·4·200·0.3·2.2 ≈ 317 N < the required F_e = 1000·37/8.3 = 4458 N. Third, the starting torque reaches 2.5T = 301 N·m, and the A-belt instantly slips out of the wedge and flies off. Root cause: the belt profile does not match the groove wedge angle, so the tension cannot be converted into grip.
① The belt profile must match the pulley-groove wedge angle (A/B profiles 34°; SPA/SPB/SPZ narrow V-belts 13° small wedge angle); they must not be mixed
② Revert to the designed SPA/SPB narrow V-belts: higher per-belt capacity, deep wedging, no slip
③ For selection, compute the torque T = 9550P/n, then look up the belt profile's rated-torque table to choose the belt count
④ Before fitting a new belt, verify that its top width and wedge angle match the pulley-groove cross-section drawing
⑤ Set the tension to the manufacturer's F0 value and recheck with a tension gauge to prevent under-tensioning and groove escape
⑥ Replace the pulley once groove wear exceeds 0.5 mm or the groove surface is polished, otherwise any belt will slip
⑦ After the first 30 min of running, stop and recheck the tension to take up run-in elongation
FT_Belt & Chain Drive Design