E41-846 · Belt Drive Selection · Feed Crusher · ★★★★
On a crusher (75 kW) the locking screws of the V-belt pulley's taper-lock bushing worked loose; the pulley ran eccentrically and vibrated, the belt flapped violently and broke, the bearing housing cracked, and the machine was down for a day of emergency repair.
First, a taper-lock bushing grips the shaft by friction, with locking torque M = k·F_shaft·d_taper/2; loosening of the screws dropped the gripping force F_shaft from the design value of 30 kN to 8 kN. Second, an eccentricity e = 2 mm produced a pulley centrifugal force F_c = m_e·e·ω² = 20·0.002·(157)² ≈ 985 N acting cyclically on the belt, raising the alternating flapping stress σ_a threefold. Third, the vibration frequency f = ω/2π = 25 Hz was close to the belt's natural frequency, causing resonance that broke the belt and cracked the bearing housing within a few hours. Root cause: failure of the taper-lock bushing's fastening.
① The taper-lock bushing screws must be tightened to the manufacturer's torque (e.g. ≥ 90 N·m for an M12 screw) with lock washers / Loctite
② Recheck the torque 24 h after installation to take up initial settling
③ Fit the pulley with an axial stop screw to prevent loosening
④ Keep oil off the mating faces of the taper-lock bushing and shaft (to keep the friction grip) and secure with Loctite
⑤ Retighten periodically (every 500 h) and check that runout ≤ 0.1 mm
⑥ For high-torque pulleys, use a lock nut plus a tab washer as double insurance
⑦ Add vibration monitoring and stop to investigate if it exceeds 4.5 mm/s
FT_Belt & Chain Drive Design