E41-856 · Belt Drive Selection · Circulating Water Pump · ★★★
During maintenance of a water pump (22 kW), the V-belt was mistakenly overtensioned; after 3 months of operation the motor bearings burned out and the shaft bent, and teardown revealed indentations on the bearing raceways.
First, the design tension F0 should make F_e = F0·μ·e^(μα) just sufficient; over-tensioning raised F0 from the design 800 N to 1500 N. Second, the bearing radial load F_r ≈ 2·F0·sin(α/2) = 2·1500·sin(17°) = 877 N far exceeded a large share of the bearing's rated dynamic load C, giving a life L10 = (C/F_r)^3·10^6 = (20e3/877)^3·10^6 ≈ 1.2e8 revolutions ≈ 3 months (the design should be > 2 years). Third, the over-tensioning also over-compressed the belt itself, causing early failure. [Root cause] Excessive tensioning.
① Set the tension F0 strictly per the manufacturer's table and measure it with a tension gauge; never over-tighten by feel
② After the new belt has run in, re-tension only up to the design value and then stop; do not add further force
③ The bearing load F_r = 2F0·sin(α/2) must be ≤ the bearing rating; check it during selection
④ Use an automatic tensioner for constant force to avoid over-tightening by hand
⑤ Select bearings with a high dynamic load rating and allow a life > 2 years
⑥ Check bearing temperature and abnormal noise weekly
⑦ Do not tension by feel