E41-857 · Belt Drive Selection · Marine Ventilation Fan · ★★
On a marine ventilation fan (3 kW), an ordinary V-belt grew mold and its surface turned powdery in the high-humidity engine room; after 8 months its strength had dropped 60% and the belt broke.
First, a relative humidity > 85% caused condensation on the ordinary rubber surface, and mold multiplied by feeding on the plasticizer and secreted organic acids that attacked the rubber. Second, the aging rate rises with humidity: at 85% RH the life is about 1/3 shorter than at 50% RH, and after 8 months the strength fell from 100% to 40%. Third, mold corrosion made the belt surface shed powder and lowered the friction coefficient μ, so slipping and heating accelerated the degradation. [Root cause] A mold-resistant belt was not selected.
① High-humidity/engine-room service must use a mold-treated belt (rubber containing a fungicide)
② State the humidity condition in the selection and choose the material from the weather-resistance table
③ Improve ventilation and dehumidification, keeping humidity < 80%
④ Periodically wipe the belt surface with a fungicide
⑤ Check for mold patches every quarter; replace the belt as soon as powdering appears
⑥ Do not use an ordinary belt in high humidity
⑦ Fit humidity monitoring on critical equipment
FT_Belt & Chain Drive Design