E41-858 · Belt Drive Selection · Legacy Equipment Retrofit · ★★★
In a retrofit of legacy equipment an SPB narrow V-belt replaced the original B-profile belt, but the pulley grooves were not changed (B-profile grooves); the belt wedge was left unsupported and slipped, losing speed, and the new belt was worn flat within half a month.
First, the SPB narrow V-belt has a 34° wedge angle but a 13 mm top width and a deeper groove, whereas the B-profile groove has a 17 mm top width and is shallower; when the SPB belt sits in a B-groove the middle of the wedge face is unsupported and only the top and bottom make local contact, cutting the effective friction area by 50%. Second, the contact pressure p = F_n/A rose 2× above the allowable value → rapid wedge-face wear. Third, the shallow wedging reduced F_f = F0·μ·e^(μα), causing slip and heating. [Root cause] The belt profile was changed but the pulley grooves were not.
① Changing to a narrow V-belt requires changing the matching pulley grooves at the same time (SPB grooves for SPB belts, with matching top width/wedge angle/groove depth)
② Check the belt cross-section drawing against the pulley-groove drawing before the retrofit
③ Never change only the belt without the pulleys, otherwise wedging will be poor
④ A pulley groove worn beyond tolerance must be replaced, not used as it is
⑤ Test-fit on installation to confirm three-face contact with no gap
⑥ Re-tension the new belt after run-in
⑦ Leave machining allowance for the pulley grooves in the retrofit
FT_Belt & Chain Drive Design