Knowledge Base › Selection Error Cases › Wrong high-temperature chain selection (furnace area)

Wrong high-temperature chain selection (furnace area)

E41-961 · Chain Drive Selection · Furnace-Area Chain Drive · ★★★

Problem Description

In a furnace area a plain chain was used at 200℃; it annealed and softened, elongated and broke, and the furnace shut down.

Root Cause

First, a plain chain has a low tempering temperature; at 200℃ it over-tempers and softens, losing 30% of its strength. Second, once softened the link plates stretch plastically and break. Third, the furnace shut down. [Root cause] Insufficient temperature resistance.

Corrective Solution

① For high temperatures (>150℃) use a high-temperature chain (alloy steel / high tempering temperature)
② Leave margin on the working temperature in the selection
③ Add thermal insulation to reduce the temperature
④ Do not use a plain chain at high temperature
⑤ Periodically check for softening
⑥ Add temperature monitoring
⑦ On break, check temperature

Checklist

Reference

FT_Belt & Chain Drive Design

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL