E41-962 · Chain Drive Selection · Pulsating-Load Chain Drive · ★★★★
Under a pulsating load a chain ran for half a year before the link plates cracked and broke and the chain dropped.
First, a pulsating load gives the link plates a large stress amplitude σ_a; the fatigue life is N = (σ_a/σ_-1)^(-b), and a pulsating load gives a higher σ_a than a steady load → N drops. Second, the fatigue limit was reached after half a year and the plates cracked. Third, the chain dropped. [Root cause] Fatigue.
① For a pulsating load select by fatigue with a safety factor ≥ 2
② Verify the link-plate stress amplitude σ_a against the fatigue limit
③ Add a flywheel to clip peaks
④ Select a high-fatigue chain (shot-peened)
⑤ Do not select directly on a steady load
⑥ Periodically check for cracks
⑦ Check for fatigue whenever the chain breaks
FT_Belt & Chain Drive Design