Problem Description

After the hydraulic lock was installed the cylinder could not be locked; under holding pressure the cylinder descended 5 mm per minute.

Root Cause

The O-ring groove on the mounting face was too shallow and the control ports X/Y were connected the wrong way round, so the pilot-operated check valve was opened unintentionally.

Corrective Solution

① Verify the connection direction of control ports X/Y
② Check the depth of the O-ring groove
③ Confirm a 24 h pressure-holding test with no leakage