Knowledge Base › Selection Error Cases › Hydraulic valve sticking caused by an inappropriate hydraulic filter rating

Hydraulic valve sticking caused by an inappropriate hydraulic filter rating

E41-674 · Hydraulic Component Selection · Hydraulic System Contamination · ★★★★

Problem Description

The directional valve spool jammed frequently, and the oil cleanliness was NAS 1638 Class 12 (requirement ≤ Class 9).

Root Cause

The return filter rating was 25 μm while the servo valve spool clearance is only 2~5 μm, so 5~25 μm contaminants could not be intercepted.

Corrective Solution

① Choose a filter rating ≤10 μm (β₁₀ ≥ 100)
② Add a bypass off-line filtration system
③ Test the oil NAS class every month

Checklist

Reference

FT_Hydraulic & Pneumatic Design

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »