Knowledge Base › Selection Error Cases › System pressure fluctuation caused by an undersized hydraulic accumulator

System pressure fluctuation caused by an undersized hydraulic accumulator

E41-677 · Hydraulic Component Selection · Accumulator Pressure Fluctuation · ★★★★

Problem Description

During the holding phase the pressure fell from 16 MPa to 10 MPa within 5 min, so the pressure could not be held.

Root Cause

The accumulator capacity of 4 L was too small with an effective volume of only 0.232 L, whereas 43 L is actually needed to compensate for leakage.

Corrective Solution

① Size the accumulator from the holding time and leakage rate
② Set the precharge pressure at 0.6~0.75 times the working pressure
③ Check the bladder nitrogen pressure regularly

Checklist

Reference

FT_Hydraulic & Pneumatic Design

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »