Knowledge Base › Selection Error Cases › Premature pump wear caused by improper selection of hydraulic oil viscosity

Premature pump wear caused by improper selection of hydraulic oil viscosity

E41-681 · Hydraulic Component Selection · Hydraulic Oil Viscosity · ★★★★

Problem Description

After 6 months of operation with VG46 hydraulic oil the piston pump body heated to 85℃ and the volumetric efficiency dropped from 95% to 70%.

Root Cause

At 55℃ the viscosity of VG46 drops to 22 cSt and the oil film thickness is only 1.3 μm (boundary lubrication), so the slipper wore.

Corrective Solution

① Select the viscosity for the working temperature (optimum 20~40 cSt)
② Use VG68 where the ambient temperature is high
③ Piston pumps must use anti-wear hydraulic oil

Checklist

Reference

FT_Hydraulic & Pneumatic Design

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »