Problem Description

The hydraulic pump set ran with high vibration of 15 mm/s, and the motor bearing failed once every 3 months.

Root Cause

The coupling coaxiality deviation was 0.1 mm radial and 0.08° angular; the pump pulsation coupled with the misalignment excitation, causing pressure pulsation.

Corrective Solution

① Adjust coaxiality to ≤0.05 mm
② Check the coupling elastomer regularly
③ Fit pipe clamps to secure the piping