E41-680 · Hydraulic Component Selection · Hydraulic Pump Set Vibration · ★★★
The hydraulic pump set ran with high vibration of 15 mm/s, and the motor bearing failed once every 3 months.
The coupling coaxiality deviation was 0.1 mm radial and 0.08° angular; the pump pulsation coupled with the misalignment excitation, causing pressure pulsation.
① Adjust coaxiality to ≤0.05 mm
② Check the coupling elastomer regularly
③ Fit pipe clamps to secure the piping