Cylinder drift caused by the wrong center position of the hydraulic directional valve

E41-679 · Hydraulic Component Selection · Directional Valve Center Position · ★★★

Problem Description

With the O-type center position of the three-position four-way valve, after power was cut the cylinder under heavy load descended slowly at 10 mm/min.

Root Cause

With the O-type center position, leakage through the spool clearance was about 0.8 L/min.

Corrective Solution

① For heavy-load locking use a Y-type center position + hydraulic lock
② Check the spool leakage
③ A pilot-operated check valve holds pressure more reliably

Checklist

Reference

FT_Hydraulic & Pneumatic Design

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL