Knowledge Base › Selection Error Cases › Pressure oscillation caused by an excessively long remote pressure-adjusting line of the hydraulic relief valve

Pressure oscillation caused by an excessively long remote pressure-adjusting line of the hydraulic relief valve

E41-689 · Hydraulic Component Selection · Relief Valve Pressure-Adjusting Oscillation · ★★★

Problem Description

The relief valve's remote pressure-adjusting line was 15 m long, and the system pressure oscillated between 10 and 14 MPa.

Root Cause

The large volume of the remote line together with the damping orifice of the pilot valve formed a hydraulic spring system, producing self-excited oscillation.

Corrective Solution

① Remote pressure-adjusting line length < 5 m
② Provide a damping throttle orifice at the remote pressure-adjusting port
③ Pipe diameter Φ6–Φ10 mm

Checklist

Reference

FT_Hydraulic & Pneumatic Design