Manifold Design Error Causing Oilway Cross-Port Leakage

E41-695 · Hydraulic Component Selection · Manifold Cross-Port Leakage · ★★★★★

Problem Description

Oil crossed between ports A and B in the manifold; pressure dropped from 16MPa to 14MPa.

Root Cause

The oilway wall was only 1.5mm (standard ≥3mm); the aluminum alloy creep-thinned under high pressure and ruptured.

Corrective Solution

① Wall between oilways ≥3mm
② Use drill jigs for cross-drilling (position accuracy ±0.1mm)
③ After machining, do a 1.5× pressure test

Checklist

Reference

FT_Hydraulic & Pneumatic Design

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »