E41-695 · Hydraulic Component Selection · Manifold Cross-Port Leakage · ★★★★★
Oil crossed between ports A and B in the manifold; pressure dropped from 16MPa to 14MPa.
The oilway wall was only 1.5mm (standard ≥3mm); the aluminum alloy creep-thinned under high pressure and ruptured.
① Wall between oilways ≥3mm
② Use drill jigs for cross-drilling (position accuracy ±0.1mm)
③ After machining, do a 1.5× pressure test
FT_Hydraulic & Pneumatic Design