Runaway Caused by Missing Counterbalance Valve Under Negative-Load Conditions in Hydraulic Systems

E41-696 · Hydraulic Component Selection · Negative-Load Runaway · ★★★★★

Problem Description

When the winch lowered a 5 t heavy load, the speed ran out of control and the load accelerated downward.

Root Cause

With no counterbalance valve to provide back pressure, the motor outlet went straight to the tank, and the load torque drove the motor to rotate freely at overspeed.

Corrective Solution

① A counterbalance valve must be installed in the negative-load circuit
② Set the counterbalance valve pressure to 1.3 times the load pressure
③ Install a normally closed brake in the hoisting system

Checklist

Reference

FT_Hydraulic & Pneumatic Design

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »